Fullerton Park Reservation, Articles A

303.3 Beveled. 552(a) and 1 CFR part 51. Some amusement rides and attractions that have unique designs and features are not addressed by these requirements. 505.9 Fittings. Toilet facilities or bathing facilities that are provided as part of a cell shall comply with 603. Inside handrails on switchback or dogleg stairs and ramps shall be continuous between flights or runs. The International Symbol of Accessibility shall comply with Figure 703.7.2.1. Where coat hooks or shelves are provided in toilet compartments, at least one of each type complying with 604.8.3 shall be provided in toilet compartments required to comply with 213.3.1. Teeing Ground. The height and position of a platform must be coordinated with the floor of the vehicles it serves to minimize the vertical and horizontal gaps, in accordance with the ADA Accessibility Guidelines for Transportation Vehicles (36 CFR Part 1192). 404.3.2 Maneuvering Clearance. Where clustered single user toilet rooms or bathing facilities are permitted to use exceptions to 213.2, toilet rooms or bathing facilities complying with 603 shall be identified by the International Symbol of Accessibility complying with 703.7.2.1 unless all toilet rooms and bathing facilities comply with 603. Where at least one public pay telephone is provided serving a hospital emergency room, hospital recovery room, or hospital waiting room, at least one public TTY shall be provided at each location. 802.1.4 Approach. Where possible, the height of the transfer step should be minimized to decrease the distance an individual is required to lift up or move down to reach the next step to gain access. Designs that limit the number of transfers required from a wheelchair or mobility device to the ride seat are encouraged. A bench complying with 903 shall be provided within the room. TTYs required at a public pay telephone shall be permanently affixed within, or adjacent to, the telephone enclosure. The clear floor space shall be positioned for parallel approach to the side of the bed. Work Area Equipment. All visible alarm appliances provided within the residential dwelling unit for building fire alarm notification shall be activated upon activation of the building fire alarm in the portion of the building containing the residential dwelling unit. (1) An alteration that affects or could affect the usability of or access to an area of a facility that contains a primary function shall be made so as to ensure that, to the maximum extent feasible, the path of travel to the altered area and the restrooms, telephones, and drinking fountains serving the altered area, are readily accessible to and usable by individuals with disabilities, including individuals who use wheelchairs, unless the cost and scope of such alterations is disproportionate to the cost of the overall alteration. A building or facility containing one or more guest room(s) for sleeping that provides accommodations that are primarily short-term in nature. For the purposes of the application of this section, the term sleeping room is intended to be used interchangeably with the term guest room as it is used in the transient lodging standards. 409.4.5 Illumination Levels. Controls and operating mechanisms shall be unobstructed when the lift is in use and shall comply with 309.4. Edge protection is required only where railings, guards, or handrails are provided on a fishing pier or platform. 1009.3.2 Submerged Depth. A change to a building or facility that affects or could affect the usability of the building or facility or portion thereof. Signs that provide direction to or information about interior spaces and facilities of the site shall comply with 703.5. To ensure communication within the facility, as well as on commercial lines, provide telephone interface jacks that are compatible with both digital and analog signal use. ), 42 inches (1065 mm) (Add 6 inches (150 mm) if closer and latch are provided. 1009.4.4 Surface. When using a transfer device to access an amusement ride, the least number of transfers and the shortest distance is most usable. Control panels shall be centered on a side wall. A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view. EXCEPTION: Where platforms serve vehicles operating on existing track or track laid in existing roadway, the slope of the platform parallel to the track shall be permitted to be equal to the slope (grade) of the roadway or existing track. 407.4.8.2.1 Signal Type. Aisles shall comply with 403. Topic: Floor Plans. 206.2.3.1 Stairs and Escalators in Existing Buildings. 609.4 Position of Grab Bars. All appliance controls shall comply with 309. Although areas used exclusively by employees for work are not required to be fully accessible, consider designing such areas to include non-required turning spaces, and provide accessible elements whenever possible. There can be multiple areas containing a primary function in a single building. 308.1 General. Within a building or facility, at least one door, doorway, or gate serving each room or space complying with these requirements shall comply with 404. 407.4.6.4.1 Height. Ramp landing slopes specified by 405.7.1 shall be permitted to be 1:20 maximum. 216.8 Toilet Rooms and Bathing Rooms. 404.2.8.1 Door Closers and Gate Closers. Footrests shall be provided and shall move with the seat. 202.3.1 Prohibited Reduction in Access. Where speech synthesis cannot be supported, dynamic alphabetic output shall not be required to be audible. 304.3.2 T-Shaped Space. Chapter 4: Entrances, Doors, and Gates - United States Access Board 407.4.8.2 Audible Indicators. ASTM F 1487-01 Standard Consumer Safety Performance Specification for Playground Equipment for Public Use (see 106.5). Each 10 feet (3050 mm) maximum of linear pier edge serving boat slips shall contain at least one continuous clear opening 60 inches (1525 mm) wide minimum. For example, 806 addresses guest rooms in transient lodging facilities while 902 contains the technical specifications for dining surfaces. PDF Americans with Disabilities Act (ADA) Standards - United States Access Where provided, saunas and steam rooms shall comply with 612. The provisions of Chapter 6 shall apply where required by Chapter 2 or where referenced by a requirement in this document. Boat slips complying with 1003.3.1 shall be dispersed throughout the various types of boat slips provided. EXCEPTION: In key stations and existing intercity rail stations, existing direct connections shall not be required to comply with 404. Wheelchair accessible compartments shall comply with 604.8.1. However, an ADA house plan doesn't make it strictly a design for the disabled. Glazed openings in residential dwelling units required to comply with 809 shall not be required to comply with 229. EXCEPTION: Drive-up only depositories shall not be required to comply with 309. It is also important to place signs at intervals in the station where passengers in the vehicle will be able to see a sign when the vehicle is either stopped at the station or about to come to a stop in the station. The centerline of the water closet shall be 12 inches (305 mm) minimum and 18 inches (455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment specified in 604.8.2. 406.1 General. Braille dots shall have a domed or rounded shape and shall comply with Table 703.3.1. 228.2 Mail Boxes. To accommodate the widest range of users, provide ramps with the least possible running slope and, wherever possible, accompany ramps with stairs for use by those individuals for whom distance presents a greater barrier than steps, e.g., people with heart disease or limited stamina. A turning space complying with 304.2 and 304.3 shall be provided in load and unload areas. 206.7.9 Team or Player Seating. 206.4.4.3 Key Stations and Intercity Rail Stations. Portable and in-line amplifiers can be used with some phones but are not practical at most public phones covered by these requirements. Advisory 232.2 General Holding Cells and General Housing Cells Exception. Providing an aquatic wheelchair made of non-corrosive materials and designed for access into the water will protect the water from contamination and avoid damage to personal wheelchairs or other mobility aids. In addition, medical care facilities that do not specialize in the treatment of conditions that affect mobility shall disperse the accessible patient bedrooms required by section 223.2.1 of the 2010 Standards in a manner that is proportionate by type of medical specialty. 703.5.1 Finish and Contrast. 230.1 General. This exception for protruding objects applies to the ride devices, not to circulation areas or accessible routes in the queue lines or the load and unload areas. Temporary buildings or facilities covered by these requirements include, but are not limited to, reviewing stands, temporary classrooms, bleacher areas, stages, platforms and daises, fixed furniture systems, wall systems, and exhibit areas, temporary banking facilities, and temporary health screening facilities. 802.2.2.2 Lines of Sight Between Heads. The location of controls shall not require reaching across burners. 306.3.4 Clearance Reduction. (1) When a commercial facility is located in a private residence, the portion of the residence used exclusively as a residence is not covered by this subpart, but that portion used exclusively in the operation of the commercial facility or that portion used both for the commercial facility and for residential purposes is covered by the new construction and alterations requirements of this subpart. The top of the gripping surface shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above transfer walls. Golf facilities shall comply with 238. 407.4.7.2 Keypads. In a building or facility permitted to use the exceptions to 206.2.3 or permitted by 206.7 to use a platform lift, elevators complying with 408 shall be permitted. 1008.2.6.1 Accessibility. If the row length in the 2nd and 3rd quartile of a row is insufficient to accommodate the required number of companion seats and wheelchair spaces, the additional companion seats and wheelchair spaces shall be permitted to be located in the 1st and 4th quartile of the row. (3) Apartments or townhouse facilities that are provided by or on behalf of a place of education, which are leased on a year-round basis exclusively to graduate students or faculty and do not contain any public use or common use areas available for educational programming, are not subject to the transient lodging standards and shall comply with the requirements for residential facilities in sections 233 and 809 of the 2010 Standards. Locate soap and towel dispensers so that they are conveniently usable by a person at the accessible lavatory. The terms designated public transportation and specified public transportation are defined by the Department of Transportation at 49 CFR 37.3 in regulations implementing the Americans with Disabilities Act. Although covered entities are permitted to limit the scope of an alteration to individual elements, the alteration of multiple elements within a room or space may provide a cost-effective opportunity to make the entire room or space accessible. For example, awnings and their supporting structures cannot reduce the minimum required vertical clearance. In this example, an exterior or interior platform lift could be used to provide an accessible entrance or to coordinate one or more interior floor levels. EXCEPTION: In existing elevators, buttons shall be permitted to be recessed. A transfer platform shall be provided at the head of each transfer system. Where toilet facilities and bathing facilities are provided, they shall comply with 213. Passing spaces shall be either: a space 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum; or, an intersection of two walking surfaces providing a T-shaped space complying with 304.3.2 where the base and arms of the T-shaped space extend 48 inches (1220 mm) minimum beyond the intersection. 804.6.2 Operable Parts. Medical care facilities that are subject to this part shall comply with the provisions of the 2010 Standards applicable to medical care facilities, including, but not limited to, sections 223 and 805. The common use or public use system interface shall include the capability of supporting voice and TTY communication with the residential dwelling unit interface. The adjacent surfaces at transitions at curb ramps to walks, gutters, and streets shall be at the same level. Accessible routes serving play areas shall comply with Chapter 4 except as modified by 1008.2. Where a seat is provided in a standard roll-in shower compartment, it shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back wall to a point within 3 inches (75 mm) of the compartment entry. Each transfer step shall be 8 inches (205 mm) high maximum. Verbal annunciators shall have a frequency of 300 Hz minimum and 3000 Hz maximum. Access aisles serving vehicle pull-up spaces shall be 60 inches (1525 mm) wide minimum. Power operated doors and gates shall remain open for 20 seconds minimum when activated. 408.3.1 Sliding Doors. (2) If physical construction or alterations commence on or after September 15, 2010, and before March 15, 2012, then new construction and alterations subject to this section may comply with one of the following: the 2010 Standards, UFAS, or the 1991 Standards except that the elevator exemption contained at section 4.1.3(5) and section 4.1.6(1)(k) of the 1991 Standards shall not apply. For example, both a bank lobby and the banks employee areas such as the teller areas and walk-in safe are primary function areas. A destination-oriented elevator system provides lobby controls enabling passengers to select floor stops, lobby indicators designating which elevator to use, and a car indicator designating the floors at which the car will stop. In residential dwelling units, grab bars shall not be required to be installed in toilet or bathrooms provided that reinforcement has been installed in walls and located so as to permit the installation of grab bars complying with 604.5. Hospitals, rehabilitation facilities, psychiatric facilities and detoxification facilities shall comply with 223.2. Raised diving boards and diving platforms shall not be required to comply with these requirements or to be on an accessible route. 804.6.1 Clear Floor or Ground Space. The provisions of Chapter 10 shall apply where required by Chapter 2 or where referenced by a requirement in this document. For example, a concert hall has 20 boxes, each of which contains 10 seats, totaling 200 seats. ), 36 inches The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (405 mm) maximum. Employee work areas, or portions of employee work areas, other than raised courtroom stations, that are less than 300 square feet (28 m2) and elevated 7 inches (180 mm) or more above the finish floor or ground where the elevation is essential to the function of the space shall not be required to comply with these requirements or to be on an accessible route. 608.5 Controls. Where an alteration includes alterations to an entrance, and the building or facility has another entrance complying with 404 that is on an accessible route, the altered entrance shall not be required to comply with 206.4 unless required by 202.4. Except for light switches, where redundant controls are provided for a single element, one control in each space shall not be required to comply with 309. A golf car passage may not be substituted for other accessible routes to be located outside the boundary of the course. Restricted Entrance. Catch Pool. The space between the grab bar and projecting objects above shall be 12 inches (305 mm) minimum.